Resistance Meter with 2A rating Innova I-63C

DIGITAL MICRO OHM METER

 INNOVA I-63C 

INNOVA digital Micro Ohm meter, model I-63C is a highly reliability 3½ Digit instrument suitable for measurement of resistivity of copper wires from 7/0 SWG to 50 SWG, resistance of cables, windings coils, heater elements and contact resistances of switches, relays etc. Innova I-63C has been designed to provide stable, repeatable and quick read outs of resistance. The resistance meter uses a 4 terminal measurement so that resistance of test leads and contacts are eliminated from test results. Actual value of resistor is directly displayed in the seven segment 12.5 mm display.

Digital Ohm Meter
Specifications:
Measurement Range : Eight ranges, from 1 micro Ohm to 19.99 K Ohm.
Range (OHMS)    Nominal Test Current Accuracy
0-1999u
2.00 A+/- 0.3% +2 Digits
0-19.99m
0.90 A+/- 0.2% +2 Digits
0-199.9m
0.90 A+/- 0.2% +2 Digits
0-1.999
100mA+/- 0.2% +2 Digits
0-19.99
10.0mA+/- 0.2% +2 Digits
0-199.9
1.00mA+/- 0.2% +2 Digits
0-1999
0.100mA+/- 0.2% +2 Digits
0-19.99K
0.010mA+/- 0.2% +2 Digits

WARM UP time for rated Accuracy is 5 Minutes.
INPUT VOLTAGE : 230V AC +/- 10% , 10W approx.
OVER RANGE : ‘1’ appears.

TEST PROCEDURE
1. TO DETERMINE THE RESISTIVITY OF COPPER WIRES.
ZERO SETTING: Connect the test leads -V & +V only. Do not connect -I & +I leads. Selector switch should be in 1999u Ohm position. Switch ‘ON’ power and stabilise instrument for 5 Minutes.

Set Zero by zero setting knob. Best Zero setting is when ‘-’ sign blinks. During measurement,zero setting may be made by removing +I lead even while the other leads are connected to the unit under test. Range of 199.9m Ohms and 19.99 Ohms do not need Zero setting and stabilization.

Connect sample conductor in 4 terminal connection as follows:

-I & + I = Current Leads , -V & +V =,Potential Leads.
L= the instrument indicates resistance of conductor in Length L, the distance between potential leads should be kept 1 meter for convenience. Keep current leads well away from potential leads.Take care that clip -I should NOT touch-V &+V directly except through conductor.

2. MEASUREMENT OF RESISTANCE OF TRANSFORMERS,MOTORS ETC.
Connect leads in 2 or 4 terminal arrangement. Switch’ON’ power. Change range if Required. Wait for a few seconds for a stable reading. Switch off power and disconnect leads and change over to next measurement. Do not disconnect leads when instrument is ‘ON’.

3. CALCULATION OF HEATER RESISTANCE
V²/W = R
where V=Heater operating voltage
W= Wattage of heater
R=Resistance of heater.

4. MEASUREMENT OF TEMPERATURE RISE
Of copper winding by increase in resistance (IS-9678-1980).

 
where
T2 = Temperature in Deg. C of winding at the end of the test.
R2 = Resistance of winding at the end of the test.
T1 = Temperature in Deg. C of winding (cold) at the moment of initial resistance
measurement,and
R1 = Initial resistance of winding.

5. INSTRUMENT ADJUSTMENT & CALIBRATION.

Test instruments required:
1. Std. 200mV DC meter of 4 ½ digit of known accuracy.
2 .Std. resistance of 1m Ohms,10m Ohms, 100m Ohms, 1 Ohm ,10 Ohms, 1K Ohm & 10 K Ohms.

PROCEDURE:
• Connect 10 Ohms std resistor to the resitance meter. Switch ‘ON’ Power. Clip Std voltmeter across clips -V & +V. Adjust test current by preset P5 so that Std Voltmeter reads 75mV.
• Adjust instruments indication by preset on DPM to read value of std 10 Ohms resistor.
• Change range to 1.999 Ohms,Connect 1 Ohm std resistor. Adjust test current by adjusting preset P4 so that the instrument displays value of std 1 Ohms resistor.
• Set all other ranges likewise. All ranges must be adjusted by connecting resistors in 4 Terminal connection. Please recheck calibration using the same resistors.
• Please send this manual with the resistance meter whenever it is sent to a laboratory for re-calibration.
• Recommended re-calibration cycle of the resistance meter is 1 Year.

6. OPERATIONAL SAFETY
Extreme care must be taken while calibrating the instrument as there are dangers of high voltage inside the resistance meter.


Material available at Store:
Industrial Supply Syndicate
54, Ezra Street, Kolkata - 700001
Phone: +91 33 22350923, 08961089611

Buy Resistance Meter Online on IndiaMeters.in

Keywords: Digital Resistance Meter, Resistance Meter, Digital Ohms Meter, Winding Resistance Meter

Low resistance measurement, ohm meter, ohm meter kolkata, resistance meter kolkata, resistance meter for cable, resistance meter for transformer, ohms meter for transformer, ohm meter for transformer

Comments

  1. Thanks for sharing the informative blog on Resistance Meter and importance regarding it. Follow the blog on working principle of Contact Resistance Meter, it'll definitely help you to clear some important points regarding the Contact Resistance.

    ReplyDelete
  2. Nice Blog!! Thanks for sharing such an informative blog. this blog is really very helpful for the searcher and you will discover the working principle of the Contact Resistance Meter. SB Electrotech is one of the famous manufacturers and suppliers of Contact Resistance Meter. You're doing a fantastic job. for information visit our site:https://www.sbelectrotech.com/contact-resistance-meter/

    ReplyDelete

Post a Comment

Popular posts from this blog

ELCB Tester for periodic testing of ELCB / RCCB / RCBO

Schneider EM6400NG - Multifunction Energy Meter

Hioki PQ3100 Power Quality Analyser